1.
Front Cardiovasc Med ; 10: 1256420, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38034383

RESUMO

This study aims to assess whether the On-X aortic valved conduit better restores normal valvular and ascending aortic hemodynamics than other commonly used bileaflet mechanical valved conduit prostheses from St. Jude Medical and Carbomedics by using same-day transthoracic echocardiography (TTE) and 4D flow magnetic resonance imaging (MRI) examinations. TTE and 4D flow MRI were performed back-to-back in 10 patients with On-X, six patients with St. Jude (two) and Carbomedics (four) prostheses, and 36 healthy volunteers. TTE evaluated valvular hemodynamic parameters: transvalvular peak velocity (TPV), mean and peak transvalvular pressure gradient (TPG), and effective orifice area (EOA). 4D flow MRI evaluated the peak systolic 3D viscous energy loss rate (VELR) density and mean vorticity magnitude in the ascending aorta (AAo). While higher TPV and mean and peak TPG were recorded in all patients compared to healthy subjects, the values in On-X patients were closer to those in healthy subjects (TPV 1.9 ± 0.3 vs. 2.2 ± 0.3 vs. 1.2 ± 0.2 m/s, mean TPG 7.4 ± 1.9 vs. 9.2 ± 2.3 vs. 3.1 ± 0.9 mmHg, peak TPG 15.3 ± 5.2 vs. 18.9 ± 5.2 vs. 6.1 ± 1.8 mmHg, p < 0.001). Likewise, while higher VELR density and mean vorticity magnitude were recorded in all patients than in healthy subjects, the values in On-X patients were closer to those in healthy subjects (VELR: 50.6 ± 20.1 vs. 89.8 ± 35.2 vs. 21.4 ± 9.2 W/m3, p < 0.001) and vorticity (147.6 ± 30.0 vs. 191.2 ± 26.0 vs. 84.6 ± 20.5 s-1, p < 0.001). This study demonstrates that the On-X aortic valved conduit may produce less aberrant hemodynamics in the AAo while maintaining similar valvular hemodynamics to St. Jude Medical and Carbomedics alternatives.

2.
J Magn Reson Imaging ; 2023 Nov 21.
Artigo em Inglês | MEDLINE | ID: mdl-37987516

RESUMO

BACKGROUND: MRI-derived left atrial (LA) longitudinal strain has been shown to be a marker for mitral regurgitation, but the utility of LA circumferential strain remains unclear. PURPOSE: To assess feasibility and reproducibility of LA circumferential strain, identify changes in mitral regurgitation patients compared to healthy volunteers, and determine strain's association with mitral regurgitation severity and cardiac function. STUDY TYPE: Retrospective. POPULATION: 52 mitral regurgitation patients, 12 healthy volunteers. FIELD STRENGTH/SEQUENCE: Steady-state free precession cine and 2D phase contrast sequences at 1.5T. ASSESSMENT: Peak LA circumferential strain was computed in each of three short-axis slices (superior, mid, and inferior) and longitudinal strain computed from long-axis slices using MRI feature-tracking software. Strain test-retest reproducibility was determined from two repeat studies in healthy volunteers. STATISTICAL TESTS: LA circumferential strain test-retest reproducibility was assessed by intra-class correlation coefficient (ICC). Strain was compared between cohorts using Student's t-test or Mann-Whitney U. Mitral regurgitation severity association with strain and LV function was assessed using Spearman correlation and multivariable regression. Significance was defined as P < 0.05. RESULTS: LA circumferential strain assessment was feasible in all subjects with moderate reproducibility in the superior (ICC = 0.74), mid LA (ICC = 0.71), and inferior LA (ICC = 0.63). In mitral regurgitation patients, LA circumferential strain was significantly lower in the superior (11.86% [6.5%,19.2%] vs. 18.73% ± 6.7%) and mid LA slices (18.41% ± 9.5% vs. 28.7% ± 10.4%) compared to healthy volunteers. Mitral regurgitation severity significantly associated with mid LA circumferential strain (ß = -0.03) and LAV significantly associated with superior LA circumferential strain (ß = -2.09), both independent of LA longitudinal strain and CO. DATA CONCLUSION: LA circumferential strain assessment is feasible with moderate reproducibility. Compared to healthy volunteers, patients had significantly lower LA circumferential strain. Mitral regurgitation severity and LAV were significantly associated with LA circumferential strain independent of LA longitudinal strain. EVIDENCE LEVEL: 3 TECHNICAL EFFICACY: Stage 2.

3.
Eur J Radiol ; 150: 110233, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35278980

RESUMO

BACKGROUND: Left ventricular thrombus (LVT) formation is a frequent and serious complication of myocardial infarction (MI). How global LV flow characteristics are related to this phenomenon is yet uncertain. In this study, we investigated LV flow differences using 4D flow cardiovascular magnetic resonance (CMR) between chronic MI patients with LVT [MI-LVT(+)] and without LVT [MI-LVT(-)], and healthy controls. METHODS: In this prospective cohort study, the 4D flow CMR data were acquired in 19 chronic MI patients (MI-LVT(+), n = 9 and MI-LVT(-), n = 10) and 9 age-matched controls. All included subjects were in sinus rhythm. The following LV flow parameters were obtained: LV flow components (direct, retained, delayed, residual), mean and peak kinetic energy (KE) values (indexed to instantaneous LV volume), mean and peak vorticity values, and diastolic vortex ring properties (position, orientation, shape). RESULTS: The MI patients demonstrated a significantly larger amount of delayed and residual flow, and a smaller amount of direct flow compared to controls (p = 0.02, p = 0.03, and p < 0.001, respectively). The MI-LVT(+) patients demonstrated numerically increased residual flow and reduced retained and direct flow in comparison to MI-LVT(-) patients. Systolic mean and peak LV blood flow KE values were significantly lower in MI patients compared to controls (p = 0.04, p = 0.03, respectively). Overall, the mean and peak LV vorticity values were significantly lower in MI patients compared to controls. The mean and peak systolic vorticity at the basal level were significantly higher in MI-LVT(+) than in MI-LVT(-) patients (p < 0.01, for both). The vortex ring core during E-wave in MI-LVT(+) group was located in a less tilted orientation to the LV compared to MI-LVT(-) group (p < 0.01). CONCLUSIONS: Chronic MI patients with LVT express a different distribution of LV flow components, irregular vorticity vector fields, and altered diastolic vortex ring geometric properties as assessed by 4D flow CMR. Larger prospective studies are warranted to further evaluate the significance of these initial observations.


Assuntos
Cardiopatias Congênitas , Infarto do Miocárdio , Trombose , Diástole , Humanos , Imageamento por Ressonância Magnética/métodos , Infarto do Miocárdio/complicações , Infarto do Miocárdio/diagnóstico por imagem , Estudos Prospectivos , Trombose/etiologia , Função Ventricular Esquerda
4.
J Magn Reson Imaging ; 56(2): 464-473, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35001455

RESUMO

BACKGROUND: Evaluation of aortic stiffness by pulse wave velocity (PWV) across the adult lifespan is needed to better understand normal aging in women and men. PURPOSE: To characterize PWV in the thoracic aorta using 4D flow MRI in an age- and sex-stratified cohort of healthy adults. STUDY TYPE: Retrospective. POPULATION: Ninety nine healthy participants (age: 46 ± 15 [19-79] years, 50% female), divided into young adults (<45 years) (N = 48), midlife (45-65 years) (N = 37), and later life (>65 years) (N = 14) groups. FIELD STRENGTH/SEQUENCE: 1.5 T or 3 T, 2D cine bSSFP, 4D flow MRI. ASSESSMENT: Cardiac functional parameters of end-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV) and myocardial mass were assessed by 2D cine bSSFP. PWV and aortic blood flow velocity were assessed by 4D flow MRI. Reproducibility of PWV was evaluated in a subset of nine participants. STATISTICAL TESTS: Analysis of variance, Pearson's correlation coefficient (r), linear regression, intraclass correlation coefficient (ICC). A P value < 0.05 was considered statistically significant. RESULTS: PWV increased significantly with age (young adults: 5.4 ± 0.9 m/sec, midlife: 7.2 ± 1.1 m/sec, and later life: 9.4 ± 1.8 m/sec) (r = 0.79, slope = 0.09 m/sec/year). PWV did not differ in women and men in entire sample (P = 0.40) or within age groups (young adults: P = 0.83, midlife: P = 0.17, and later life: P = 0.96). PWV was significantly correlated with EDV (r = -0.29), ESV (r = -0.23), SV (r = -0.28), myocardial mass (r = 0.21), and mean aortic blood flow velocity (r = -0.62). In the test-retest subgroup (N = 9), PWV was 6.7 ± 1.5 [4.4-9.3] m/sec and ICC = 0.75. DATA CONCLUSION: 4D flow MRI quantified higher aortic PWV with age, by approximately 1 m/sec per decade, and significant differences between young adults, midlife and later life. Reproducibility analysis showed good test-retest agreement. Increased PWV was associated with decline in cardiac function and reduced aortic blood flow velocity. This study demonstrates the utility of 4D flow MRI-derived aortic PWV for studying aging. EVIDENCE LEVEL: 2 TECHNICAL EFFICACY: Stage 2.


Assuntos
Análise de Onda de Pulso , Rigidez Vascular , Adulto , Velocidade do Fluxo Sanguíneo , Feminino , Humanos , Longevidade , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos , Adulto Jovem
5.
J Cardiovasc Magn Reson ; 23(1): 138, 2021 12 06.
Artigo em Inglês | MEDLINE | ID: mdl-34865629

RESUMO

BACKGROUND: Quantitative evaluation of mitral regurgitation (MR) in hypertrophic cardiomyopathy (HCM) by cardiovascular magnetic resonance (CMR) relies on an indirect volumetric calculation. The aim of this study was to directly assess and quantify MR jets in patients with HCM using 4D flow CMR jet tracking in comparison to standard-of-care CMR indirect volumetric method. METHODS: This retrospective study included patients with HCM undergoing 4D flow CMR. By the indirect volumetric method from CMR, MR volume was quantified as left ventricular stroke volume minus forward aortic volume. By 4D flow CMR direct jet tracking, multiplanar reformatted planes were positioned in the peak velocity of the MR jet during systole to calculate through-plane regurgitant flow. MR severity was collected for agreement analysis from a clinical echocardiograms performed within 1 month of CMR. Inter-method and inter-observer agreement were assessed by intraclass correlation coefficient (ICC), Bland-Altman analysis, and Cohen's kappa. RESULTS: Thirty-seven patients with HCM were included. Direct jet tracking demonstrated good inter-method agreement of MR volume compared to the indirect volumetric method (ICC = 0.80, p = 0.004) and fair agreement of MR severity (kappa = 0.27, p = 0.03). Direct jet tracking showed higher agreement with echocardiography (kappa = 0.35, p = 0.04) than indirect volumetric method (kappa = 0.16, p = 0.35). Inter-observer reproducibility of indirect volumetric method components revealed the lowest reproducibility in end-systolic volume (ICC = 0.69, p = 0.15). Indirect volumetric method showed good agreement of MR volume (ICC = 0.80, p = 0.003) and fair agreement of MR severity (kappa = 0.38, p < 0.001). Direct jet tracking demonstrated (1) excellent inter-observer reproducibility of MR volume (ICC = 0.97, p < 0.001) and MR severity (kappa = 0.84, p < 0.001) and (2) excellent intra-observer reproducibility of MR volume (ICC = 0.98, p < 0.001) and MR severity (kappa = 0.88, p < 0.001). CONCLUSIONS: Quantifying MR and assessing MR severity by indirect volumetric method in HCM patients has limited inter-observer reproducibility. 4D flow CMR jet tracking is a potential alternative technique to directly quantify and assess MR severity with excellent inter- and intra-observer reproducibility and higher agreement with echocardiography in this population.


Assuntos
Cardiomiopatia Hipertrófica , Insuficiência da Valva Mitral , Cardiomiopatia Hipertrófica/diagnóstico por imagem , Humanos , Imagem Cinética por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Insuficiência da Valva Mitral/diagnóstico por imagem , Variações Dependentes do Observador , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estudos Retrospectivos
6.
Am J Physiol Heart Circ Physiol ; 320(4): H1687-H1698, 2021 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-33635164

RESUMO

The purpose of this study was to directly assess (patho)physiology of intraventricular hemodynamic interplay between four-dimensional flow cardiovascular magnetic resonance imaging (4D Flow MRI)-derived vorticity with kinetic energy (KE) and viscous energy loss (EL) over the cardiac cycle and their association to ejection fraction (EF) and stroke volume (SV). Fifteen healthy subjects and thirty Fontan patients underwent whole heart 4D Flow MRI. Ventricular vorticity, KE, and EL were computed over systole (vorticity_volavg systole, KEavg systole, and ELavg systole) and diastole (vorticity_volavg diastole, KEavg diastole, and ELavg diastole). The association between vorticity_vol and KE and EL was tested by Spearman correlation. Fontan patients were grouped to normal and impaired EF groups. A significant correlation was found between SV and vorticity in healthy subjects (systolic: ρ = 0.84, P < 0.001; diastolic: ρ = 0.81, P < 0.001) and in Fontan patients (systolic: ρ = 0.61, P < 0.001; diastolic: ρ = 0.54, P = 0.002). Healthy subjects showed positive correlation between vorticity_vol versus KE (systole: ρ = 0.96, P < 0.001; diastole: ρ = 0.90, P < 0.001) and EL (systole: ρ = 0.85, P < 0.001; diastole: ρ = 0.84, P < 0.001). Fontan patients showed significantly elevated vorticity_vol compared with healthy subjects (vorticity_volavg systole: 3.1 [2.3-3.9] vs. 1.7 [1.3-2.4] L/s, P < 0.001; vorticity_volavg diastole: 3.1 [2.0-3.7] vs. 2.1 [1.6-2.8] L/s, P = 0.002). This elevated vorticity in Fontan patients showed strong association with KE (systole: ρ = 0.91, P < 0.001; diastole: ρ = 0.85, P < 0.001) and EL (systole: ρ = 0.82, P < 0.001; diastole: ρ = 0.89, P < 0.001). Fontan patients with normal EF showed significantly higher vorticity_volavg systole and ELavg systole, but significantly decreased KE avg diastole, in the presence of normal SV, compared with healthy subjects. Healthy subjects show strong physiological hemodynamic interplay between vorticity with KE and EL. Fontan patients demonstrate a pathophysiological hemodynamic interplay characterized by correlation of elevated vorticity with KE and EL in the presence of maintained normal stroke volume. Altered vorticity and energetic hemodynamics are found in the presence of normal EF in Fontan patients.NEW & NOTEWORTHY Physiologic intraventricular hemodynamic interplay/coupling is present in the healthy left ventricle between vorticity versus viscous energy loss and kinetic energy from four-dimensional flow cardiovascular magnetic resonance imaging (4D Flow MRI). Conversely, Fontan patients present compensatory pathophysiologic hemodynamic coupling by an increase in intraventricular vorticity that positively correlates to viscous energy loss and kinetic energy levels in the presence of maintained normal stroke volume. Altered vorticity and energetics are found in the presence of normal ejection fraction in Fontan patients.


Assuntos
Técnica de Fontan , Cardiopatias Congênitas/cirurgia , Ventrículos do Coração/cirurgia , Hemodinâmica , Imagem Cinética por Ressonância Magnética , Contração Miocárdica , Função Ventricular , Adolescente , Fenômenos Biomecânicos , Estudos de Casos e Controles , Criança , Feminino , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/fisiopatologia , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Imagem de Perfusão do Miocárdio , Países Baixos , Valor Preditivo dos Testes , Estudos Prospectivos , Resultado do Tratamento
7.
Int J Cardiovasc Imaging ; 37(9): 2755-2765, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33523363

RESUMO

To noninvasively assess left atrial (LA) kinetic energy (KE) in hypertrophic cardiomyopathy (HCM) patients using 4D flow MRI and evaluate coupling associations with mitral regurgitation (MR) and left ventricular outflow tract (LVOT) obstruction. Twenty-nine retrospectively identified patients with HCM underwent 4D flow MRI. MRI-estimated peak LVOT pressure gradient (∆PMRI) was used to classify patients into non-obstructive and obstructive HCM. Time-resolved volumetric LA kinetic energy (KELA) was computed throughout systole. Average systolic (KELA-avg) and peak systolic (KELA-peak) KELA were compared between non-obstructive and obstructive HCM groups, and associations to MR severity and LVOT ∆PMRI were tested.The study included 15 patients with non-obstructive HCM (58.6 [45.9, 65.2] years, 7 females) and 14 patients with obstructive HCM (51.9 [47.6, 62.6] years, 6 females). Obstructive HCM patients demonstrated significantly elevated instantaneous KELA over all systolic time-points compared to non-obstructive HCM (P < 0.05). Obstructive HCM patients also demonstrated higher KELA-avg (14.8 [10.6, 20.4] J/m3 vs. 33.4 [23.9, 61.3] J/m3, P < 0.001) and KELA-peak (22.1 [15.9, 28.7] J/m3 vs. 57.2 [44.5, 121.4] J/m3, P < 0.001) than non-obstructive HCM. MR severity was significantly correlated with KELA-avg (rho = 0.81, P < 0.001) and KELA-peak (rho = 0.79, P < 0.001). LVOT ∆PMRI was strongly correlated with KELA metrics in obstructive HCM (KELA-avg: rho = 0.86, P < 0.001; KELA-peak: rho = 0.85, P < 0.001).In HCM patients, left atrial kinetic energy, by 4D flow MRI, is associated with MR severity and the degree of LVOT obstruction.


Assuntos
Cardiomiopatia Hipertrófica , Insuficiência da Valva Mitral , Obstrução do Fluxo Ventricular Externo , Cardiomiopatia Hipertrófica/complicações , Cardiomiopatia Hipertrófica/diagnóstico por imagem , Feminino , Humanos , Imageamento por Ressonância Magnética , Insuficiência da Valva Mitral/diagnóstico por imagem , Valor Preditivo dos Testes , Estudos Retrospectivos , Obstrução do Fluxo Ventricular Externo/diagnóstico por imagem , Obstrução do Fluxo Ventricular Externo/etiologia
8.
Heart Fail Clin ; 17(1): 135-147, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33220882

RESUMO

In heart failure (HF), the impaired heart loses its ability to competently eject blood during systole or fill with blood during diastole, manifesting in multifaceted abnormal intracardiac or intravascular flow dynamics. Conventional imaging techniques are limited in their ability to evaluate multidirectional multidimensional flow alterations in HF. Four-dimensional (4-D) flow magnetic resonance imaging (MRI) has emerged as a promising technique to comprehensively visualize and quantify changes in 3-dimensional blood flow dynamics in complex cardiovascular diseases. This article reviews emerging applications of 4-D flow MRI hemodynamic markers in HF and etiologies at risk of progressing to HF.


Assuntos
Vasos Sanguíneos/diagnóstico por imagem , Insuficiência Cardíaca/diagnóstico , Hemodinâmica/fisiologia , Imagem Cinética por Ressonância Magnética/métodos , Miocárdio/patologia , Vasos Sanguíneos/fisiopatologia , Insuficiência Cardíaca/fisiopatologia , Humanos , Espectroscopia de Ressonância Magnética
9.
J Magn Reson Imaging ; 51(2): 472-480, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31257647

RESUMO

BACKGROUND: The prevalence of valvular aortic stenosis (AS) increases as the population ages. Echocardiographic measurements of peak jet velocity (Vpeak ), mean pressure gradient (Pmean ), and aortic valve area (AVA) determine AS severity and play a pivotal role in the stratification towards valvular replacement. A multimodality imaging approach might be needed in cases of uncertainty about the actual severity of the stenosis. PURPOSE: To compare four-dimensional phase-contrast magnetic resonance (4D PC-MR), two-dimensional (2D) PC-MR, and transthoracic echocardiography (TTE) for quantification of AS. STUDY TYPE: Prospective. POPULATION: Twenty patients with various degrees of AS (69.3 ± 5.0 years). FIELD STRENGTH/SEQUENCES: 4D PC-MR and 2D PC-MR at 3T. ASSESSMENT: We compared Vpeak , Pmean , and AVA between TTE, 4D PC-MR, and 2D PC-MR. Flow eccentricity was quantified by means of normalized flow displacement, and its influence on the accuracy of TTE measurements was investigated. STATISTICAL TESTS: Pearson's correlation, Bland-Altman analysis, paired t-test, and intraclass correlation coefficient. RESULTS: 4D PC-MR measured higher Vpeak (r = 0.95, mean difference + 16.4 ± 10.7%, P <0.001), and Pmean (r = 0.92, mean difference + 14.9 ± 16.0%, P = 0.013), but a less critical AVA (r = 0.80, mean difference + 19.9 ± 20.6%, P = 0.002) than TTE. In contrast, unidirectional 2D PC-MR substantially underestimated AS severity when compared with TTE. Differences in Vpeak between 4D PC-MR and TTE showed to be strongly correlated with the eccentricity of the flow jet (r = 0.89, P <0.001). Use of 4D PC-MR improved the concordance between Vpeak and AVA (from 0.68 to 0.87), and between PGmean and AVA (from 0.68 to 0.86). DATA CONCLUSION: 4D PC-MR improves the concordance between the different AS parameters and could serve as an additional imaging technique next to TTE. Future studies should address the potential value of 4D PC-MR in patients with discordant echocardiographic parameters. LEVEL OF EVIDENCE: 2 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2020;51:472-480.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/diagnóstico por imagem , Ecocardiografia , Humanos , Imageamento por Ressonância Magnética , Estudos Prospectivos , Reprodutibilidade dos Testes , Índice de Gravidade de Doença
10.
Radiology ; 293(3): 541-550, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31592729

RESUMO

Background Four-dimensional (4D) flow MRI enables the evaluation of blood flow alterations in patients with congenital bicuspid aortic valve (BAV). However, current analysis methods are cumbersome and lack the use of the volumetric data from 4D MRI. Purpose To investigate the feasibility and reproducibility of a technique that uses a catheter-like mathematical model (virtual catheter) to assess volumetric intra-aortic hemodynamics from 4D flow MRI in patients with BAV. Materials and Methods In this retrospective study, data were collected from adult patients with BAV and healthy participants who underwent aortic 4D flow MRI from November 2011 through August 2014. Reproducibility was tested in healthy study participants who underwent test-retest examinations within 2 weeks. Patients were grouped on the basis of the severity of aortic valve regurgitation (AVR) and aortic valve stenosis (AVS). A 4D virtual catheter mathematical model for probing intra-aortic hemodynamic flow was constructed as a tube with an automatically derived radius along the entire thoracic aorta centerline. Volumetric intra-aortic hemodynamics were computed from 4D flow MRI only within the virtual catheter, and the following volume-normalized systolic peaks were derived: kinetic energy (KE), viscous energy loss rate (VELR), and vorticity. Hemodynamic data were presented as medians with interquartile ranges and compared by using Mann-Whitney U test and Kruskal-Wallis test. Results The study included 91 participants (57 patients [mean age, 46 years ± 12], 18 women; 34 healthy participants [mean age: 44 years ± 14], 12 women; 15 healthy participants underwent test-retest examinations). Patients showed higher VELR values compared with healthy participants (median, 31 W/m3 [interquartile range, 21-72] vs 23 W/m3 [interquartile range, 17-30], respectively; P < .001) and vorticity (69 sec-1 [interquartile range, 59-87] vs 60 sec-1 [interquartile range, 50-67], respectively; P < .001). Four-dimensional virtual catheter showed differences among different AVS and AVR grades with the highest VELR (120 W/m3; interquartile range, 99-166; P < .001) and vorticity (108 sec-1; interquartile range, 84-151; P < .001) found in severe AVS. High test-retest reproducibility was found for all virtual catheter-derived metrics (intraclass correlation, 0.80 ± 0.07; coefficient of variation, 9% ± 3). Conclusion The proposed four-dimensional (4D) virtual catheter technique enabled reproducible automated evaluation of volumetric intra-aortic hemodynamics alterations from 4D flow MRI in patients with bicuspid aortic valve. © RSNA, 2019 Online supplemental material is available for this article. See also the editorial by Mitsouras and Hope in this issue.


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Valva Aórtica/anormalidades , Doenças das Valvas Cardíacas/diagnóstico por imagem , Doenças das Valvas Cardíacas/fisiopatologia , Hemodinâmica , Imageamento por Ressonância Magnética/métodos , Adulto , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Doença da Válvula Aórtica Bicúspide , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos , Interface Usuário-Computador , Viscosidade
12.
J Cardiovasc Magn Reson ; 21(1): 43, 2019 07 25.
Artigo em Inglês | MEDLINE | ID: mdl-31340834

RESUMO

BACKGROUND: We hypothesize that dobutamine-induced stress impacts intracardiac hemodynamic parameters and that this may be linked to decreased exercise capacity in Fontan patients. Therefore, the purpose of this study was to assess the effect of pharmacologic stress on intraventricular kinetic energy (KE), viscous energy loss (EL) and vorticity from four-dimensional (4D) Flow cardiovascular magnetic resonance (CMR) imaging in Fontan patients and to study the association between stress response and exercise capacity. METHODS: Ten Fontan patients underwent whole-heart 4D flow CMR before and during 7.5 µg/kg/min dobutamine infusion and cardiopulmonary exercise testing (CPET) on the same day. Average ventricular KE, EL and vorticity were computed over systole, diastole and the total cardiac cycle (vorticity_volavg cycle, KEavg cycle, ELavg cycle). The relation to maximum oxygen uptake (VO2 max) from CPET was tested by Pearson's correlation or Spearman's rank correlation in case of non-normality of the data. RESULTS: Dobutamine stress caused a significant 88 ± 52% increase in KE (KEavg cycle: 1.8 ± 0.5 vs 3.3 ± 0.9 mJ, P < 0.001), a significant 108 ± 49% increase in EL (ELavg cycle: 0.9 ± 0.4 vs 1.9 ± 0.9 mW, P < 0.001) and a significant 27 ± 19% increase in vorticity (vorticity_volavg cycle: 3441 ± 899 vs 4394 ± 1322 mL/s, P = 0.002). All rest-stress differences (%) were negatively correlated to VO2 max (KEavg cycle: r = - 0.83, P = 0.003; ELavg cycle: r = - 0.80, P = 0.006; vorticity_volavg cycle: r = - 0.64, P = 0.047). CONCLUSIONS: 4D flow CMR-derived intraventricular kinetic energy, viscous energy loss and vorticity in Fontan patients increase during pharmacologic stress and show a negative correlation with exercise capacity measured by VO2 max.


Assuntos
Agonistas de Receptores Adrenérgicos beta 1/administração & dosagem , Circulação Coronária/efeitos dos fármacos , Dobutamina/administração & dosagem , Teste de Esforço , Tolerância ao Exercício/efeitos dos fármacos , Técnica de Fontan , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/cirurgia , Hemodinâmica/efeitos dos fármacos , Imagem Cinética por Ressonância Magnética , Imagem de Perfusão do Miocárdio/métodos , Consumo de Oxigênio/efeitos dos fármacos , Adolescente , Feminino , Cardiopatias Congênitas/fisiopatologia , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Valor Preditivo dos Testes , Estudos Prospectivos , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
13.
Eur Heart J Cardiovasc Imaging ; 20(3): 323-333, 2019 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-30060051

RESUMO

AIMS: To non-invasively assess intraventricular viscous energy loss (EL) and proportionality to kinetic energy (KE) in Fontan patients using 4D flow magnetic resonance imaging (MRI) and compare to healthy controls. METHODS AND RESULTS: Thirty Fontan patients and 15 controls underwent 4D flow MRI. Ventricular EL was computed and normalized by end-diastolic volume (EDV). EL over the cardiac cycle (ELcycle) relative to the average kinetic energy (KEcycle) was quantified using a dimensionless index, ELindex (ELcycle/KEcycle). EL was significantly elevated in Fontan patients compared to controls (ELcycle/EDV: 3.7 vs. 2.6 J/m3, P = 0.001). Fontan patients with inflow of blood entering a ventricle, which leaves that ventricle through a ventricular septal defect to the aorta, defined as discordant inflow-to-outflow showed significantly higher EL compared to patients with inflow of blood into the same ventricle from which the blood is ejected into the aorta, defined as concordant inflow-to-outflow (ELcycle/EDV: 6.8 vs. 3.2 J/m3, P = 0.001). EL was not significantly different in Fontan patients with a systemic left vs. a systemic right ventricle (ELcycle/EDV: 3.5 vs. 3.6 J/m3, P = 0.91). ELindex was significantly elevated in Fontan patients compared to controls (ELindex: 0.4 vs. 0.2, P < 0.001). Highest ELindex was found in Fontan patients with discordant inflow-to-outflow compared to concordant inflow-to-outflow (0.5 vs. 0.3, P = 0.01). CONCLUSION: Fontan patients show disproportionate intraventricular EL relative to KE. Intraventricular EL is elevated in these patients compared to healthy controls, and highest EL is found in patients with discordant inflow-to-outflow.


Assuntos
Velocidade do Fluxo Sanguíneo/fisiologia , Técnica de Fontan/métodos , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/cirurgia , Imageamento Tridimensional , Imagem Cinética por Ressonância Magnética/métodos , Adulto , Estudos de Casos e Controles , Feminino , Humanos , Cinética , Masculino , Pessoa de Meia-Idade , Prognóstico , Valores de Referência , Medição de Risco , Estatísticas não Paramétricas , Resultado do Tratamento
14.
Eur Heart J Cardiovasc Imaging ; 20(1): 108-117, 2019 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-30137274

RESUMO

Aims: The main aim of this study was to characterize changes in the left ventricular (LV) blood flow kinetic energy (KE) using four-dimensional (4D) flow cardiovascular magnetic resonance imaging (CMR) in patients with myocardial infarction (MI) with/without LV thrombus (LVT). Methods and results: This is a prospective cohort study of 108 subjects [controls = 40, MI patients without LVT (LVT- = 36), and MI patients with LVT (LVT+ = 32)]. All underwent CMR including whole-heart 4D flow. LV blood flow KE wall calculated using the formula: KE=12 ρblood . Vvoxel . v2, where ρ = density, V = volume, v = velocity, and was indexed to LV end-diastolic volume. Patient with MI had significantly lower LV KE components than controls (P < 0.05). LVT+ and LVT- patients had comparable infarct size and apical regional wall motion score (P > 0.05). The relative drop in A-wave KE from mid-ventricle to apex and the proportion of in-plane KE were higher in patients with LVT+ compared with LVT- (87 ± 9% vs. 78 ± 14%, P = 0.02; 40 ± 5% vs. 36 ± 7%, P = 0.04, respectively). The time difference of peak E-wave KE demonstrated a significant rise between the two groups (LVT-: 38 ± 38 ms vs. LVT+: 62 ± 56 ms, P = 0.04). In logistic-regression, the relative drop in A-wave KE (beta = 11.5, P = 0.002) demonstrated the strongest association with LVT. Conclusion: Patients with MI have reduced global LV flow KE. Additionally, MI patients with LVT have significantly reduced and delayed wash-in of the LV. The relative drop of distal intra-ventricular A-wave KE, which represents the distal late-diastolic wash-in of the LV, is most strongly associated with the presence of LVT.


Assuntos
Ventrículos do Coração/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Infarto do Miocárdio/diagnóstico por imagem , Trombose/diagnóstico por imagem , Adulto , Velocidade do Fluxo Sanguíneo , Estudos de Casos e Controles , Meios de Contraste , Diástole/fisiologia , Inglaterra , Feminino , Ventrículos do Coração/fisiopatologia , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/fisiopatologia , Países Baixos , Estudos Prospectivos , Trombose/fisiopatologia , Função Ventricular Esquerda
15.
Eur J Cardiothorac Surg ; 55(6): 1202-1210, 2019 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-30590476

RESUMO

OBJECTIVES: In patients with the Fontan circulation, systemic venous return flows passively towards the lungs. Because of the absence of the subpulmonary ventricle, favourable blood flow patterns with minimal energy loss are clinically relevant. The region where the inferior vena cava, the hepatic veins and the extracardiac conduit join (IVC-conduit junction) is a potential source of increased energy loss. The aim of this study was to evaluate the relationship between geometry and blood flow patterns in the IVC-conduit junction with associated kinetic energy and energy loss using 4-dimensional flow magnetic resonance imaging (MRI). METHODS: Fourteen extracardiac conduit-Fontan patients underwent 4-dimensional flow MRI. The IVC-conduit junctions were ranked into 3 groups for 3 categories: the geometry, the flow complexity and the conduit mean velocity. The relative increase in the mean velocity from the IVC to the conduit (representing IVC-conduit mismatch) was determined. The peak kinetic energy and mean kinetic energy and energy loss were determined and normalized for volume. RESULTS: In 4 of 14 patients, adverse geometries led to helical flow patterns and/or acute changes in flow direction. For each category, the most adverse IVC-conduit junctions were associated with an approximate 2.3-3.2-fold and 2.0-2.9-fold increase in kinetic energy and energy loss, respectively. The IVC-conduit mismatch is strongly correlated with the mean kinetic energy and energy loss (r = 0.80, P = 0.001 and ρ = 0.83, P < 0.001, respectively) and with body surface area in patients with 16- mm conduits (r = 0.88, P = 0.010). CONCLUSIONS: The IVC-conduit junction is a potential source of increased energy loss. Junctions with increased energy loss showed: (i) a distorted geometry leading to adverse blood flow patterns and/or (ii) the IVC-conduit mismatch. Sixteen-millimetre conduits appear to be inadequate for older patients.


Assuntos
Velocidade do Fluxo Sanguíneo/fisiologia , Técnica de Fontan/métodos , Cardiopatias Congênitas/diagnóstico , Processamento de Imagem Assistida por Computador/métodos , Imagem Cinética por Ressonância Magnética/métodos , Veia Cava Inferior/diagnóstico por imagem , Pré-Escolar , Feminino , Cardiopatias Congênitas/fisiopatologia , Cardiopatias Congênitas/cirurgia , Humanos , Masculino , Reprodutibilidade dos Testes , Estudos Retrospectivos , Veia Cava Inferior/fisiopatologia
16.
J Cardiovasc Magn Reson ; 20(1): 61, 2018 08 30.
Artigo em Inglês | MEDLINE | ID: mdl-30165869

RESUMO

BACKGROUND: Myocardial infarction (MI) leads to complex changes in left ventricular (LV) haemodynamics that are linked to clinical outcomes. We hypothesize that LV blood flow kinetic energy (KE) is altered in MI and is associated with LV function and infarct characteristics. This study aimed to investigate the intra-cavity LV blood flow KE in controls and MI patients, using cardiovascular magnetic resonance (CMR) four-dimensional (4D) flow assessment. METHODS: Forty-eight patients with MI (acute-22; chronic-26) and 20 age/gender-matched healthy controls underwent CMR which included cines and whole-heart 4D flow. Patients also received late gadolinium enhancement imaging for infarct assessment. LV blood flow KE parameters were indexed to LV end-diastolic volume and include: averaged LV, minimal, systolic, diastolic, peak E-wave and peak A-wave KEiEDV. In addition, we investigated the in-plane proportion of LV KE (%) and the time difference (TD) to peak E-wave KE propagation from base to mid-ventricle was computed. Association of LV blood flow KE parameters to LV function and infarct size were investigated in all groups. RESULTS: LV KEiEDV was higher in controls than in MI patients (8.5 ± 3 µJ/ml versus 6.5 ± 3 µJ/ml, P = 0.02). Additionally, systolic, minimal and diastolic peak E-wave KEiEDV were lower in MI (P < 0.05). In logistic-regression analysis, systolic KEiEDV (Beta = - 0.24, P < 0.01) demonstrated the strongest association with the presence of MI. In multiple-regression analysis, infarct size was most strongly associated with in-plane KE (r = 0.5, Beta = 1.1, P < 0.01). In patients with preserved LV ejection fraction (EF), minimal and in-plane KEiEDV were reduced (P < 0.05) and time difference to peak E-wave KE propagation during diastole increased (P < 0.05) when compared to controls with normal EF. CONCLUSIONS: Reduction in LV systolic function results in reduction in systolic flow KEiEDV. Infarct size is independently associated with the proportion of in-plane LV KE. Degree of LV impairment is associated with TD of peak E-wave KE. In patient with preserved EF post MI, LV blood flow KE mapping demonstrated significant changes in the in-plane KE, the minimal KEiEDV and the TD. These three blood flow KE parameters may offer novel methods to identify and describe this patient population.


Assuntos
Interpretação de Imagem Assistida por Computador/métodos , Imagem Cinética por Ressonância Magnética/métodos , Imagem de Perfusão do Miocárdio/métodos , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico por imagem , Adulto , Idoso , Velocidade do Fluxo Sanguíneo , Estudos de Casos e Controles , Meios de Contraste/administração & dosagem , Circulação Coronária , Feminino , Gadolínio DTPA/administração & dosagem , Humanos , Masculino , Pessoa de Meia-Idade , Miocárdio/patologia , Valor Preditivo dos Testes , Estudos Prospectivos , Infarto do Miocárdio com Supradesnível do Segmento ST/patologia , Infarto do Miocárdio com Supradesnível do Segmento ST/fisiopatologia , Função Ventricular Esquerda
17.
Int J Cardiovasc Imaging ; 34(6): 905-920, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29305740

RESUMO

The aim of the current study was to assess the scan-rescan reproducibility of left ventricular (LV) kinetic energy (KE), viscous energy loss (EL) and vorticity during diastole from four-dimensional flow magnetic resonance imaging (4D flow MRI) in healthy subjects. Twelve volunteers (age 27 ± 3 years) underwent whole-heart 4D flow MRI twice in one session. In-scan consistency was evaluated by correlation between KE and EL. ELindex was computed to measure the amount of EL relative to KE over diastole. Scan-rescan analysis was performed to test reproducibility of volumetric measurements of KE, EL, ELindex and vorticity in the LV over early (E) and late (A) diastolic filling. In-scan consistency between KE and EL was strong-excellent (E-filling scan1: r = 0.92, P < 0.001; scan2: ρ = 0.96, P < 0.001 and A-filling scan1: ρ = 0.87, P < 0.001; scan2: r = 0.99, P < 0.001). For the majority of subjects (10 out of 12), KE and EL measures showed good to strong reproducibility. However, with a wide range of agreement [intraclass correlation (ICC): 0.64-0.95] and coefficients of variation (CV) ≤ 25%. ELindex showed strong reproducibility for all 12 subjects with a strong ICC (0.94, P < 0.001) and a CV of 9%. Scan-rescan reproducibility of volumetric vorticity showed good-excellent ICCs (0.83-0.95) with CVs ≤ 11%. In conclusion, the current study shows strong-excellent in-scan consistency and overall good agreement between scans for 4D flow MRI assessment of left ventricular kinetic energy, energy loss and vorticity over diastole. However, substantial differences between the scans were also found in some parameters in two out of twelve subjects. Strong reproducibility was found in the dimensionless ELindex, which measures the amount of viscous energy loss relative to the average kinetic energy over diastole.


Assuntos
Diástole/fisiologia , Coração/diagnóstico por imagem , Coração/fisiologia , Imageamento por Ressonância Magnética/métodos , Função Ventricular Esquerda/fisiologia , Adulto , Fenômenos Biomecânicos , Velocidade do Fluxo Sanguíneo , Técnicas de Imagem Cardíaca/métodos , Voluntários Saudáveis , Humanos , Imageamento Tridimensional/métodos , Masculino , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estudos Retrospectivos , Fatores de Tempo , Adulto Jovem
18.
J Magn Reson Imaging ; 47(1): 272-281, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-28470915

RESUMO

PURPOSE: To validate three widely-used acceleration methods in four-dimensional (4D) flow cardiac MR; segmented 4D-spoiled-gradient-echo (4D-SPGR), 4D-echo-planar-imaging (4D-EPI), and 4D-k-t Broad-use Linear Acquisition Speed-up Technique (4D-k-t BLAST). MATERIALS AND METHODS: Acceleration methods were investigated in static/pulsatile phantoms and 25 volunteers on 1.5 Tesla MR systems. In phantoms, flow was quantified by 2D phase-contrast (PC), the three 4D flow methods and the time-beaker flow measurements. The later was used as the reference method. Peak velocity and flow assessment was done by means of all sequences. For peak velocity assessment 2D PC was used as the reference method. For flow assessment, consistency between mitral inflow and aortic outflow was investigated for all pulse-sequences. Visual grading of image quality/artifacts was performed on a four-point-scale (0 = no artifacts; 3 = nonevaluable). RESULTS: For the pulsatile phantom experiments, the mean error for 2D PC = 1.0 ± 1.1%, 4D-SPGR = 4.9 ± 1.3%, 4D-EPI = 7.6 ± 1.3% and 4D-k-t BLAST = 4.4 ± 1.9%. In vivo, acquisition time was shortest for 4D-EPI (4D-EPI = 8 ± 2 min versus 4D-SPGR = 9 ± 3 min, P < 0.05 and 4D-k-t BLAST = 9 ± 3 min, P = 0.29). 4D-EPI and 4D-k-t BLAST had minimal artifacts, while for 4D-SPGR, 40% of aortic valve/mitral valve (AV/MV) assessments scored 3 (nonevaluable). Peak velocity assessment using 4D-EPI demonstrated best correlation to 2D PC (AV:r = 0.78, P < 0.001; MV:r = 0.71, P < 0.001). Coefficient of variability (CV) for net forward flow (NFF) volume was least for 4D-EPI (7%) (2D PC:11%, 4D-SPGR: 29%, 4D-k-t BLAST: 30%, respectively). CONCLUSION: In phantom, all 4D flow techniques demonstrated mean error of less than 8%. 4D-EPI demonstrated the least susceptibility to artifacts, good image quality, modest agreement with the current reference standard for peak intra-cardiac velocities and the highest consistency of intra-cardiac flow quantifications. LEVEL OF EVIDENCE: 1 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2018;47:272-281.


Assuntos
Coração/diagnóstico por imagem , Imageamento Tridimensional , Imagem Cinética por Ressonância Magnética , Imagens de Fantasmas , Adulto , Valva Aórtica/diagnóstico por imagem , Artefatos , Velocidade do Fluxo Sanguíneo , Imagem Ecoplanar , Feminino , Voluntários Saudáveis , Ventrículos do Coração/diagnóstico por imagem , Humanos , Interpretação de Imagem Assistida por Computador , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Valva Mitral/diagnóstico por imagem , Valores de Referência , Reprodutibilidade dos Testes , Sístole , Adulto Jovem
19.
J Magn Reson Imaging ; 47(2): 511-522, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-28640394

RESUMO

PURPOSE: To evaluate the in-scan and scan-rescan consistency of left ventricular (LV) in- and outflow assessment from 1) 2D planimetry; 2) 4D flow magnetic resonance imaging (MRI) with retrospective valve tracking, and 3) 4D flow MRI with particle tracing. MATERIALS AND METHODS: Ten healthy volunteers (age 27 ± 3 years) underwent multislice cine short-axis planimetry and whole-heart 4D flow MRI on a 3T MRI scanner twice with repositioning between the scans. LV in- and outflow was compared from 1) 2D planimetry; 2) 4D flow MRI with retrospective valve tracking over the mitral valve (MV) and aortic valve (AV), and 3) 4D flow MRI with particle tracing through forward and backward integration of velocity data. RESULTS: In-scan consistency between MV and AV flow volumes is excellent for both 4D flow MRI methods with r ≥ 0.95 (P ≤ 0.001). In-scan AV and MV flow by retrospective valve tracking shows good to excellent correlations versus AV and MV flow by particle tracing (r ≥ 0.81, P ≤ 0.004). Scan-rescan SV assessment by 2D planimetry shows excellent reproducibility (intraclass correlation [ICC] = 0.98, P < 0.001, coefficient of variation [CV] = 7%). Scan-rescan MV and AV flow volume assessment by retrospective valve tracking shows strong reproducibility (ICCs ≥ 0.89, P ≤ 0.05, CVs = 12%), as well as by forward and backward particle tracing (ICCs ≥ 0.90, P ≤ 0.001, CVs ≤ 11%). Multicomponent particle tracing shows good scan-rescan reproducibility (ICCs ≥ 0.81, P ≤ 0.007, CVs ≤ 16%). CONCLUSION: LV in- and outflow assessment by 2D planimetry and 4D flow MRI with retrospective valve tracking and particle tracing show good in-scan consistency and strong scan-rescan reproducibility, which indicates that both 4D flow MRI methods are reliable and can be used clinically. LEVEL OF EVIDENCE: 2 Technical Efficacy Stage: 2 J. Magn. Reson. Imaging 2018;47:511-522.


Assuntos
Ventrículos do Coração/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Função Ventricular/fisiologia , Adulto , Velocidade do Fluxo Sanguíneo/fisiologia , Feminino , Humanos , Masculino , Valores de Referência , Reprodutibilidade dos Testes , Estudos Retrospectivos